7460 Series - Glass Tube Flowmeter
There is nothing else like it in the industry. This 75 mm scale glass tube meter offers economical 304 stainless steel case construction with vertical connections.
DESCRIPTION
| Metering Tube | Borosilicate Kinglass |
| Internal Components | Standard: 316L SS |
| Optional: Hastelloy® C-276 | |
| Fitting Material | Standard: 316L SS |
| Optional: PVC | |
| Inlet/Outlet Fittings | FNPT Vertical |
| O-Ring | Standard: Viton® |
| Optional: Buna N, EPR, and Kalrez® | |
| Case and Covers | 304 SS case |
| Polycarbonate shield | |
PERFORMANCE
| Capacities | Water | 0.5 to 25 GPM | |
| Air | 2 to 14 SCFM | ||
| Scale | 80 mm (3”) direct reading, detachable | ||
| Accuracy | ± 5% of full scale flow | ||
| Turndown | 10:1 | ||
| Repeatability | 1% | ||
| Maximum Temperature | 316L SS fittings | Gases | 250° F (121° C) |
| 316L SS fittings | Liquids | 200° F (93° C) | |
| PVC fittings | Liquids | 110° F (43° C) | |
| Maximum Pressure | 316L SS | 200 psig | |
| PVC fittings | 150 psig | ||
| Ambient Temperature | 33° F to 125° F (1° C to 52° C) | ||
OPTIONS
| Certified Calibrations | Conform to ISA RP 16.6 | |
| Scales | Any volumetric unit | |
FLOATS

SPECIFICATIONS
| Order Number |
Full Scale Flo GPM — Water |
Full Scale Fl SCFM — Air |
Float Number |
Float Type |
Press. Dr In W.C. |
Tube Size |
Tube Number* |
Connection Size |
| 41 | .5 | 2.0 | ½-LPG-04 | LP | – | 4G (.50”) | ½-751-4G | ½” - FNPT |
| 42 | 1.0 | 4.0 | ½-LPG-05 | LP | 5 | 4G (.50”) | ½-751-4G | ½” - FNPT |
| 43 | 2.0 | 8.2 | ½-SLG-01 | SL | 9 | 4G (.50”) | ½-751-4G | ½” - FNPT |
| 44 | 3.5 | 14.0 | ⅝-SLP-01 | SL | 9 | 4P (.625”) | ⅝-753-4P | ½” - FNPT |
| 45 | 5.6 | 22.0 | ⅝-SLP-02 | SL | 11 | 4P (.625”) | ⅝-753-4P | ½” - FNPT |
| 46 | 7.4 | 29.0 | ⅝-SLP-03 | SL | 15 | 4P (.625”) | ⅝-753-4P | ½” - FNPT |
| 61 | 10.0 | 40.0 | 1-GSP-01 | GS | 16 | 6P (1”) | 1-749-6P | 1” - FNPT |
| 62 | 15.0 | 68.0 | 1-SLG-02 | SL | 24 | 6P (1”) | 1-749-6P | 1” - FNPT |
| 63 | 25.0 | – | 1-SLG-01 | SL | 42 | 6P (1”) | 1-749-6P | 1” - FNPT |
* Tubes designated “G” have rib-guided floats. Tubes designated “P” have pole-guided floats.
Footnotes: Because of the compressible nature of gas, meters used in this service may be subject to float bounce:
- The meter is used in very low pressure applications.
- There are more than two pipe diameters between the meter and a control valve.
- The gas being metered is a low specific gravity gas.
- The meter is operating below 20% of full scale flow.
- Back pressure is insufficient to stabilize the float.
DIMENSION DIAGRAM (INCHES)

ORDERING:
Use the following guide to determine the specific product number you require.
Example: 746 - 1 - 2 - 1 - 63W
| 746 | |||||
| Meter Series | Fitting Material | Float Material | O-Ring Material | Order Number | Scale |
| 316L SS - 1 PVC - 3 (Not for air) |
316L SS - 2 Hastelloy® 276-C - 4 |
EPR - 1 |
see Specifications table |
Water GPM - W Air SCFM - A Non Standard - N |