7100 Series

  • Low flow, high pressure applications; CRNs available
  • 400°F maximum temperature; 4,000 psig maximum pressure
  • Magnetically coupled dial display; 60mm scale
  • 0.6 to 25 gph water; 1 to 120 scfh air

7200-3

7200 Series

  • Low cost, low maintenance applications where quality is important
  • Precision machined and polished acrylic meter with 127mm scale
  • In-line 3/8” to 2” NPT connections
  • 1 to 200 gpm water; 4 to 245 scfm air

7310-3

7310 Series

  • An economical polysulfone meter in a stainless steel case
  • Stainless steel, Hastelloy or Teflon wetted parts
  • 127mm detachable, direct reading scale
  • 0.5 to 160 gpm water; 6.1 to 330 scfm air

7330 Series

  • Union ends for ease of installation; available with alarm options
  • Stainless steel, Hastelloy or Teflon wetted parts
  • 127mm detachable, direct reading scale
  • 0.5 to 160 gpm water; Liquid Service Only

7430 Series

  • Low flow, gas purge applications; alarm options available
  • 250°F max temp.; 200 psig max pressure
  • 65mm or 150mm detachable, direct reading scales
  • Horizontal connections; designed for panel mounting
  • 66 to 70,000 cc per minute air 0.72 to 1800 cc per minute water

7440-3-1

7440 Series

  • Low flow, gas purge, chemical dosing applications; alarm options available
  • 250°F max temperture; 200 psig max pressure
  • 65mm or 150mm detachable, direct reading scales
  • Vertical connections and stainless steel frame
  • 66 to 70,000 cc per min. air 0.72 to 1800 cc per min. water

7450-2

7450 Series

  • Sturdy side plate construction; material options for chemical resistance
  • Panel-mountable with optional control valve
  • 75mm or 150mm detachable direct reading scales
  • 0.48 to 7.4 gpm water; 2 to 20 scfm air

7459

7459 Series

  • Sturdy side plate construction with polycarbonate shield
  • High accuracy meter; 250mm detachable, direct reading scale
  • 250°F maximum temperature; 350 psig maximum pressure
  • 0.22 to 100 gpm water; 0.9 to 350 scfm air

7460 Series

  • Excellent value in utility glass meter in stainless steel case
  • In-line FNPT connections; 75mm detachable, direct reading scale
  • 0.5 to 25 gpm water; 2 to 68 scfm air

7470 Series

  • Excellent value in municipal glass meter in stainless steel case
  • In-line FNPT connections; 127mm detachable, direct reading scale
  • 0.25 to 116 gpm water; 1 to 245 scfm air

7480 Series

  • Excellent value in high-flow glass meter in stainless steel case
  • In-line FNPT connections; 250mm detachable, direct reading scale
  • 0.22 to 132 gpm water; 0.9 to 350 scfm air

7510sm

7510 & 7511 Series

  • Block type, precision machined and polished acrylic meter
  • Panel mount with in-line connections
  • 50mm, 75mm, 100mm, 127mm, 250mm scales
  • 0.12 to 20 gpm water; 0.04 to 60 scfm air

7520_7530

7520 & 7530 Series

  • Block type, precision machined and polished acrylic meter
  • Panel mount with horizontal connections and optional metering valve
  • 50mm, 75mm, 100mm, 127mm, 250mm scales
  • 0.12 to 20 gpm water; 0.04 to 60 scfm air

7610-2-1

7610 Series

  • Versatile and exceptionally durable, fully enclosed glass meter
  • In-line connections; material and alarm options
  • 127mm detachable direct reading scale
  • 0.25 to 116 gpm water; 1 to 245 scfm air

7650-2

7650 Series

  • Designed for chemical resistance and purity
  • Stainless steel tie rod frame for added safety
  • 80mm direct reading scale
  • 0.25 to 26gpm water; Liquid Service Only

7710 Series

  • Superior accuracy and versatility at an excellent value; CRNs available
  • Offered with NPT or flange connections; 4-20mA output available
  • Magnetically coupled dial display; 120mm dual scale
  • 0.55 to 450 gpm water; 4 to 100 scfm air

7720 Series

  • Unique, Type 1, Grade 1 all PVC meter; NPT or flange connections
  • Hastelloy wetted parts for corrosive applications
  • 120mm detachable, direct reading scale; 4-20mA output available
  • 0.55 to 450 gpm water; Liquid Service Only

7750 Series

  • 250mm end-to-end length with flange connections.
  • Welded construction, no elastomeric O-rings used
  • 4-20mA transmitter output available; 120mm detachable scale
  • 0.55 to 16.5 gpm water; 2.2 to 76 scfm air

7910-2

7910 Series

  • 70 flow ranges in 7 tube sizes; 250mm scale
  • Stainless steel case with dual port connections for ease of installation
  • 200°F maximum temperature; 300 psig maximum pressure
  • 0.22 to 132 gpm water; 0.9 to 350 scfm air

9000 Silver Series

  • Removable glass metering tube for ease of maintenance
  • 35 flow ranges in 6 tube sizes; 200mm and 250mm scales
  • Vertical or horizontal NPT or flanged connections
  • 0.23 to 85 gpm water; 1.15 to 285 scfm air